INSTALLATION INSTRUCTIONS
TECHNICAL SPECIFICATION
COVERING THE FOLLOWING MODELS:
Model Gas
CAT.
Gas Type Working
Pressure
Aeration Injector Gas Rate
m
3
/h
Input kW
(Gross)
Country
High Low
CL3 BF
I
2H
Natural (G20) 20mbar 6 x 6 185 0.304 3.2 2 GB, IE
CL3 BF
I
3P
Propane (G31) 37mbar
6 x 6
90
0.120 3.2 2
GB, IE
16 x 23
CL5 BF
I
2H
Natural (G20) 20mbar 6 x 10 158 0.409 4.3 2.5 GB, IE
CL5 BF
I
3P
Propane (G31) 37mbar
6 x 10
110 0.162 4.3 2.5 GB, IE
16 x 23
EfciencyClass2-81%/NO
x
Class 4
Flue Outlet Size Ø 150mm
Flue Inlet Size Ø 100mm
Gas Inlet Connection Size Ø 8mm
RESTRICTOR REQUIREMENT
VERTICAL & HORIZONTAL FLUE TOP EXIT - VERTICAL ONLY INCLUDING OFFSET
CL3 & CL5 BF CL5 BF
Vertical Flue Height Horizontal Length Restrictor Size Vertical Flue Height Restrictor Size
500mm - 990mm 250mm - 1000mm No restrictor 3000 - 4990mm Ø 52mm (Sliding)
1000mm - 1990mm 250mm - 1000mm Ø 60mm 5000mm - 10,000mm Ø 40mm (Sliding)
2000mm - 3000mm 250mm - 1000mm Ø 52mm
Model Natural Gas LPG
Top Exit Rear Exit Top Exit Rear Exit
CL3
N/A YM581-374 N/A YM581-539
CL5
YM581-329 YM581-354 YM581-712 YM581-647