14
2. REAR FLUE
2.1 REAR FLUE KIT
YEOMAN CL BF (8526)
AR0630a
2
200mm min
550mm max
Terminal dimensions:
395 x 200 x 200 mm (H x W x D)
Guard supplied
Cut to length as required on site (see Diagram 2).
3. TOP EXIT FLUES (MIDI ONLY)
There are two types of flue terminal: horizontal (Section 3B)
and vertical (Section 3D).
3A. TOP FLUE UP AND OUT KIT
(8523/8523AN)
3.1 This flue rises vertically from the top of the appliance, then
continues horizontally outward (see Diagram 3).
The basic kit comprises:
1 x 500mm vertical length
1 x 500mm terminal length
1 x 90 degree elbow
1 x wall plate
1 x 75mm restrictor
1 x fixing screw
INSTALLATION INSTRUCTIONS
SITE REQUIREMENTS
AR1619
3
3.2 This kit provides the minimum materials. Extra lengths can
be added to the vertical and horizontal sections; refer to
Section 4.
3.3 Refer to Installation Instructions, Technical Specification
(page 14) to identify when to use a restrictor.
3B. FOR HORIZONTAL TERMINAL
INSTALLATIONS:
3.4 Decide on the terminal position.
3.5 Measure the height from the top of the appliance to the
centre of the required hole. For minimum and maximum
dimensions see Diagram 3.
3.6 To fit the flue you must have access to the top or the side
of the appliance to connect the flue.
3.7 Assemble the vertical sections making sure the top plate
and flue collar are fitted before the fluepipe.
3.8 Add the 90° elbow.
3.9 Add the horizontal section and terminal. Only the
horizontal part can be reduced in size.
3.10 A masonry installation requires the addition of a suitable
lintel to support the opening. Refer to Installation
Instructions, Technical Information for details of the flue
length.