INSTALLATION INSTRUCTIONS
INSTALLATION
6. LOG LAYOUT
LOGS MUST BE POSITIONED ACCORDING TO THE
FOLLOWING INSTRUCTIONS TO GIVE THE CORRECT
FLAME EFFECT
Small Vision Layout
6a.1 Ensure the burner tray is clean and free from any debris,
Diagram 15.
15
AR2103
The three logs that make up the fuel bed are visually
distinct and fit into specific parts on the burner tray.
6a.2 Place the rear log into position as illustrated in Diagram 16.
Ensure that the left hand edge butts up against the raised
groove in the burner tray and the back panel- see Detail A.
16
AR2103
Log 1
Detail A
6a.3 Place the second log into the left hand groove on the
burner tray and ensure it is pushed as far into the centre as
the groove will allow, Diagram 17.
14
AR2698
4.52 Connect a suitable pressure gauge to the test point located
on the inlet fitting.
Turn on the gas
Light the appliance and check for leaks
Turn the appliance to maximum and check that the supply
pressure is as stated on the data badge.
Turn off the gas and replace the test point screw
Turn the gas back on and check the test point for leaks
5. ARRANGEMENT OF FUEL BED
5.1 ADVICE ON HANDLING AND DISPOSAL OF FIRE
CERAMICS
The fuel effect of the log version of this appliance is made
from Refractory Ceramic Fibre (RCF), a material which is
commonly used for this application.
Protective clothing is not required when handling these
articles, but we recommend you follow normal hygiene
rules of not smoking, eating or drinking in the work area
and always wash your hands before eating or drinking.
To ensure that the release of RCF fibres are kept to a
minimum, during installation and servicing a HEPA filtered
vacuum is recommended to remove any dust accumulated
in and around the appliance before and after working on it.
When servicing the appliance it is recommended that the
replaced items are not broken up, but are sealed within
heavy duty polythene bags and labelled as RCF waste.
RCF waste is classed as stable, non-reactive hazardous waste
and may be disposed of at a licensed landfill site.
Excessive exposure to these materials may cause temporary
irritation to eyes, skin and respiratory tract; wash hands
thoroughly after handling the material.