INSTALLATION INSTRUCTIONS
INSTALLATION
4B TOP EXIT - UP & OUT
ENSURE THE BLACK DECORATIVE TOP AND COLLAR
ARE FITTED TO THE TOP OF THE APPLIANCE PRIOR TO
INSTALLATION OF A TOP FLUE EXIT.
THIS MUST BE POSITIONED BEFORE INSTALLING THE
FLUE.
A restrictor may be required with top exit flues. See chart
below for restrictor sizes.
VERTICAL & HORIZONTAL FLUE
Riva Vision Small & Midi BF
Vertical Flue Height Horizontal Length Restrictor Size
500mm - 990mm 250mm - 1000mm No restrictor
1000mm - 1990mm 250mm - 1000mm Ø 60mm
2000mm - 3000mm 250mm - 1000mm Ø 52mm
Wall Plate
4.20 A wall plate is supplied to secure the flue to the inside wall.
Bend the securing tab to 90° and slot the plate over the flue
before bringing the flue through the wall.
4.21 Mark the fixing holes using the wall plate as a template
The tab can be above or beneath the flue (see Diagram 10).
Flue Aperture
4.22 Mark the height from the top of the hearth to the centre
of the horizontal section (see Diagram 9).
AR0628
9
4.23 TAKE CARE TO MARK OUT THE FLUE CORRECTLY. IT IS
DIFFICULT TO MOVE AFTER INSTALLATION.
4.24 Create a 152mm (6”) diameter hole for the flue using
either:
a) a core drill, or
b) a hammer and chisel
4.25 Make good at both ends of the hole.
Flue Length
4.26 The final length of the flue pipe includes the terminal. The
terminal is the only section that can be shortened.
DO NOT SHORTEN ANY OTHER SECTION OF FLUE
PIPE.
4.27 Measure from the outside of the wall to the stop on the
90° elbow.
4.28 Fit horizontal flue section between the elbow and the
terminal at this stage, if required (see Diagram10).
AR0629
10
10mm
Wall plate
4.29 Mark the correct length all the way around the flue
terminal section (see Diagram 10).
4.30 Insert the square cardboard sleeve into the flue to
support the inner tube.
4.31 Cut through the flue and sleeve (see Diagram 11).
AR0630
11
4.32 REMOVE THE CARDBOARD REMNANTS FROM THE
FLUE.
4.33 File the cut edge smooth.