37
SERVICING INSTRUCTIONS
REPLACING PARTS
22
AR1604
7.5 To remove the electrode, disconnect the ignition lead and
undo the retaining nut. The electrode can now be removed,
note the orientation of the electrode terminal when
reassembling. See Diagram 23.
AR0616
23
7.6 To remove the thermocouple, undo the retaining nut and
withdraw the thermocouple. Undo the thermocouple from
the back of the gas valve, see Diagram 24. Reassemble in
reverse order. Do not overtighten.
AR1617
24
7.7 To remove the gasket, disconnect all the above components
and withdraw the gasket. If it is damaged, replace with a
new item. Always replace the gasket first when reassembling
the pilot components.
8. IGNITION LEAD
8.1 Gain access to the back of the pilot assembly, see Section 7
above and disconnect the ignition lead from the electrode.
8.2 Cut the cable tie securing the vida flex (if present) and pull
the lead through the vida flex.
8.3 If necessary cut any cable ties and disconnect the lead from
the control box (see Diagram 25).
AR2506a
26
Ignition lead
connection
8.4 Replace in reverse order.
8.5 Ensure the lead is passed through the vida flex, secured with
a cable tie and the red insulated end is attached to the
electrode.
Note the direction of the lead. The new lead must follow
exactly the same route.
9. GAS VALVE
Gas Inlet
Supply Pipe
Interrupter Lead Set
(Note position of red
tag lead)
Thermocouple
Connection
Pilot
Pipe
Gas
Outlet
Pipe
Earth
Connection
Stepper
Plug
Valve
Fixings
AR2505
25
25
Kommentare zu diesen Handbüchern